e Marine Group

Trace C35, C40, and C60 Charge Controller Specifications

Electrical Specifications C35 C40 C60
Voltage Configurations 12 and 24 VDC 12, 24 and 48 VDC 12 and 24 VDC
Maximum PV Open Circuit Array Voltage 55 VDC 125 VDC 55 VDC
Charging / Load Current (@ 25 °C) 35 amps DC 40 amps DC 60 amps DC
Maximum Peak Current 85 amps 85 amps 85 amps
Maximum Voltage Drop Through Controller 0.30 volts 0.30 volts 0.30 volts
Typical Operating Consumption 15 ma 15 ma 15 ma
Typical Idle Consumption 3 ma 3 ma 3 ma
Recommended Breaker Size 45 amps 50 amps 60 amps rated at 100% continuous duty
Recommended Wire Size #8 AWG #8 AWG #6 AWG at 90°
Lead Acid Battery Settings Adjustable Adjustable Adjustable
NiCad Battery Settings Adjustable Adjustable Adjustable
Load Control Mode      
      Low Voltage Reconnect Adjustable (sticker provided with unit) Adjustable (sticker provided with unit) Adjustable (sticker provided with unit)
      Low Voltage Disconnect User selectable manual or automatic reconnection - includes warning flash before disconnect and provides a one time, user selected grace period

Mechanical Specifications
Specified Temperature Range 32° F to 104° F (-0° C to 40° C) 32° F to 104° F (-0° C to 40° C) 32° F to 104° F (-0° C to 40° C)
Enclosure Type Indoor, ventilated, powder coated steel with 3/4" and 1" knockouts Indoor, ventilated, powder coated steel with 3/4" and 1" knockouts Indoor, ventilated, powder coated steel with 3/4" and 1" knockouts
Unit Weight 2.5 lb (1.2 kg) 3.0 lb (1.4 kg) 3.0 lb (1.4 kg)
Shipping 3.0 lb (1.4 kg) 3.5 lb (1.6 kg) 3.5 lb (1.6 kg)
Dimensions (H x W x D) 8.0" x 5.0" x 2.5" (20.3 cm x 12.7 cm x 6.4 cm ) 10" x 5" x 2.5" (25.4 cm x 12.7 cm x 6.35 cm) 10" x 5" x 2.5" (25.4 cm x 12.7 cm x 6.35 cm)
Shipping Dimensions (H x W x D) 12.4" x 7" x 2.5" (31.5 cm x 17.8 cm x 6.4 cm) 12.4" x 7" x 2.5" (31.5 cm x 17.8 cm x 6.4 cm) 12.4" x 7" x 2.5" (31.5 cm x 17.8 cm x 6.4 cm)
Mounting Vertical wall mount-indoor only Vertical wall mount-indoor only Vertical wall mount-indoor only
Altitude      
      Operating 15,000' (4,572 m) 15,000' (4,572 m) 15,000' (4,572 m)
      Non-Operating 50,000' (15,240 m) 50,000' (15,240 m) 50,000' (15,240 m)

Features and Options
Regulation Method Solid state, three-stage (bulk, absorption, and float), pulse width modulation
Field Adjustable Control Setpoints Two user adjustable voltage setpoints for control of loads or charging sources - settings retained if battery is disconnected
Control Panel CM, CM/R-50, or CM/R-100 - optional LCD - backlit, alphanumeric display showing battery voltage, DC amperage, cumulative amp hours, and amp hours since last reset - remote includes 50’ (15 m) or 100’ (30.5 m) cable
Equalization Charge User selectable manual or automatic equalization - every 30 days
Battery Temperature Sensor BTS - optional remote battery temperature sensor for increased charging precision

Common Specifications
Listings UL Listed to UL 1741 - 1999 and to CSA 22.2 No. 107.1-95 Standards, CE compliant

Call us toll free at (877) 432-2221

We accept credit cards VISA card MasterCard Discove/Novus Card American Express Card

Trace C35, C40, C60 Features
Back to Solar Charge Controllers