e-Marine, Inc

V25 Digital Volts Gauge from CruzPro

V25 monitor Specifications

Operating Voltage: 9.5 - 33.0 VDC (Higher voltage versions available by special order)

Current Drain: 0.018 amps nominal

Display: 4 digit LCD, 5 levels of backlighting

Data: Digital volts, high and low voltage alarm display

Ranges: 9.5 to 33.0 VDC Custom OEM versions to 60VDC

Data Output: NMEA 0183 serial 4800 BAUD, $IIXDR,V

Alarms: Built-in 85 dB audible alarm. Settable independent high and low voltage alarms

Size: 2.5" dia X 4.1" deep (61mm x 104mm) Mounting: 2-1/8" (55mm) round hole

V25 The V25 Digital Volts Gauge provides accurate low cost digital instrumentation for batteries between 9.5 and 33 Volts.

You can set independent Low and High voltage alarms. When activated, the V25 built-in 85 dB alarm will sound and the display will flash. Five levels of backlighting can be selected and all set-up, calibration constants and alarm values are saved to non-volatile memory. All constants and calibrations are pre-set during manufacture but you may alter these settings to suit your particular needs. Calibrations can be altered using the front-panel switches for battery voltage and low and high voltage alarms.

With a press of the button you can display battery voltage (9.5 to 33.0 VDC), high or low voltage alarm values. High volts and Low volts alarms can be independently set using the front panel switches and the alarm can be turned ON/OFF with the press of a single key. The V25 draws only 0.017 amps and can be left on continuously. 5 levels of backlight (including OFF) can be selected from the front panel and is saved to non-volatile memory.

The V25 outputs digital voltage data in the standard NMEA 0183 serial data line at 4800 BAUD. This ASCII information can be used to log performance, repeat the display information at a remote location (see www.cruzpro.com/rp30.html ) or for use with the CruzPro SEAviz virtual instrumentation software running under Windows on your computer (see www.cruzpro.com/seaviz.html). If NMEA 0183 serial data is not required, then the output terminal can be programmed as an external alarm output pin.

Blue Line

Call us toll free at (877) 432-2221

We accept the following credit cards:

VISA card MasterCard Discove/Novus Card

Items On Sale